Kabel Optik Aktif SFP+ 10Gb/s
Fitur
+ Ngarojong aplikasi Saluran Serat 10GBASE-SR/10G
+ Patuh kana SFP+ MSA Listrik SFF-8431
+ Patuh kana SFP+ MSA Mékanis SFF-8432
+ Laju multi-dugi ka 11.3Gbps
+ Jarak transmisi dugi ka 150m (OM3)
+ +3.3V catu daya tunggal
+ Konsumsi daya anu handap
+ Suhu kasus operasi: Komersial: 0°C dugi ka +70 °C
+ Patuh kana RoHS
+ Protéksi kecap akses pikeun A0h sareng A2h
Aplikasi
+ 10GBASE-SR dina 10.31Gbps
+ InfiniBand QDR, SDR, DDR
+ Tautan optik anu sanés
Karakteristik Listrik
| Parameter | Simbol | Menit. | Tipikal. | Maks. | Unit | Catetan | |
| Pemancar | |||||||
| Ayun Input Data Diferensial | Vdi,PP | 200 | - | 1600 | mVPP |
| |
| Impedansi Diferensial Input | ZIN | 90 | 100 | 110 | Ω |
| |
| Kasalahan Tx | Operasi Normal | VOL | 0 | - | 0.8 | V |
|
| Kasalahan Pemancar | VOH | 2.0 | - | VCC | V |
| |
| Tx_Disable | Operasi Normal | VIL | 0 | - | 0.8 | V |
|
| Nonaktipkeun Laser | VIH | 2.0 | - | VCC+0.3 | V |
| |
| Panarima | |||||||
| Kaluaran Tanggal Diferensial | Vkaluar | 370 | - | 1600 | mV |
| |
| Impedansi Diferensial Kaluaran | ZD | 90 | 100 | 110 | Ω |
| |
| Rx_LOS | Operasi Normal | VOL | 0 | - | 0.8 | V |
|
| Leungit Sinyal | VoH | 2.0 | - | VCC | V | ||
Karakteristik Optik
| Parameter | Simbol | Unit | Menit | Tipikal | Maks. | Catetan |
| Karakteristik pemancar optik | ||||||
| Laju Data | DR | Gbps | 9.953 | 10.3125 | 11.3 |
|
| Rentang Panjang Gelombang Pusat | λc | nm | 820 | 850 | 880 |
|
| Daya Pareum Laser | Poff | dBm | - | - | -45 |
|
| Ngajalankeun Daya Optik | P0 | dBm | -6.0 |
|
| 1 |
| Babandingan Punah | ER | dB | 3 | - | - |
|
| Lebar Spéktral (RMS) | RMS | nm | - |
| 0.45 |
|
| Karakteristik Panarima Optik | ||||||
| Laju Data | DR | Gbps | 9.953 | 10.3125 | 11.3 |
|
| Laju Kasalahan Bit | BER | dBm | - | - | E-12 | 2 |
| Daya Optik Input Kaleuwihan Beban | PIN | dBm | 2.4 | - | - | 2 |
| Rentang Panjang Gelombang Pusat | λc | nm | 820 | - | 880 |
|
| Sensitivitas Panarima dina Daya Rata-rata | Sen | dBm | - | - | -9.9 | 3 |
| Los Assert | LosA | dBm | -26 | - | - |
|
| Los De-Assert | LosD | dBm | - | - | -12 |
|
| Los Hysteresis | LosH | dB | 0.5 | - | - | |
Catetan:
- Digabungkeun kana 50/125 MMF.
- Diukur nganggo PRBS 231-1 pola tés @10.3125Gbps.BER=10E-12
Karakteristik Optik
| Parameter | Nilai | Unit |
| Diaméter | 3 | mm |
| Radius tikungan minimum | 30 | mm |
| Toleransi panjang | Panjangna < 1 m: +5 /-0 | cm |
| 1 m ≤panjang ≤ 4,5 m: +15 / -0 | cm | |
| 5 m ≤panjang ≤ 14,5 m: +30 / -0 | cm | |
| Panjangna ≥15.0 m +2% / -0 | m | |
| Warna kabel | Cai (OM3); Oranyeu (OM2) | |