Kabel Serat Optik Luar Ruangan Pipa Mode Tunggal G652D G657A1 GYTS 12 Inti
Data Téknis Kabel GYTS
| Barang | Parameter | |
| Tabung leupas | Bahan | PBT |
| Warna | Spéktrum warna lengkep | |
| Pangeusi | Bahan | PE |
| Warna | Hideung | |
| CSM | Bahan | Kawat baja fosfat |
| Dilapis ku waja | Bahan | Strip aluminium dilapis plastik |
| Jaket luar | Bahan | MDPE |
| Warna | Hideung | |
| Radius lentur minimum | Statis | 10 kali diaméter kabel |
| Dinamis | 20 kali diaméter kabel | |
| Ngalengkungkeun deui | Muatan:150N; jumlah siklus: 30 Teu aya atenuasi tambahan anu jelas, teu aya serat anu pegat sareng teu aya karusakan kabel. | |
| Kinerja tarik | Jangka pondok | 1500N |
| Nabrak | Jangka pondok | 1000N/100mm |
| Torsi | Muatan:150N; jumlah siklus: 10; sudut pulas:±180° Teu aya atenuasi tambahan anu atra, teu aya serat anu pegat sareng teu aya karusakan kabel. | |
| Dampak | Énergi dampak:450g×1m; radius sirah palu: 12.5mm; jumlah dampak: 5 Teu aya atenuasi tambahan anu jelas, teu aya serat putus sareng teu aya karusakan kabel. | |
Ciri serat:
| Gaya serat | Unit | SM G652D | SM G657A | MM 50/125 | MM 62.5/125 | MM OM3-300 | MM OM4-550 | |
| Kaayaan | nm | 1310/1550 | 1310/625 | 850/1300 | 850/1300 | 850/1300 | 850/1300 | |
| Atenuasi | dB/km | ≤0.34/0.22 | ≤.035/0.21 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.0/1.0 | ≤3.5/2.2 | |
| Dispersi | 1550nm | Ps/(nm*km) | ≤18 | ≤18 | ---- | ---- | ---- | ---- |
| 1625nm | Ps/(nm*km) | ≤22 | ≤22 | ---- | ---- | ---- | ---- | |
| Lebar pita | 850nm | MHZ.KM | ---- | ≥400 | ≥160 | |||
| 1300nm | MHZ.KM | ---- | ≥800 | ≥500 | ||||
| Panjang gelombang dispersi nol | nm | ≥1302 ≤1322 | ≥1302 ≤1322 | ---- | ---- | ≥ 1295, ≤1320 | ≥ 1295, ≤1340 | |
| Lamping dispersi nol | nm | ≤0.091 | ≤0.090 | ---- | ---- | ---- | ---- | |
| Serat Individu Maksimum PMD | ≤0.2 | ≤0.2 | ---- | ---- | ≤0.11 | |||
| Nilai Tautan Desain PMD | Ps(nm2*km) | ≤0.08 | ≤0.1 | ---- | ---- | ---- | ---- | |
| Panjang gelombang cutoff serat λc | nm | ≥1180 ≤1330 | ≥1180 ≤1330 | ---- | ---- | ---- | ---- | |
| Pemotongan kabel panjang gelombang λcc | nm | ≤1260 | ≤1260 | ---- | ---- | ---- | ---- | |
| MFD (Kauntungan Keuangan) | 1310nm | um | 9.2±0.4 | 9.0±0.4 | ---- | ---- | ---- | ---- |
| 1550nm | um | 10.4±0.8 | 10.1±0.5 | ---- | ---- | ---- | ---- | |
| Numerik Apertur (NA) | ---- | ---- | 0.200± 0.015 | 0.275± 0.015 | 0.200± 0.015 | 0.200± 0.015 | ||
| Léngkah (rata-rata dua arah pangukuran) | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Kalainan dina panjang sareng titik serat | dB | ≤0.05 | ≤0.05 | ≤0.10 | ≤0.10 | ≤0.10 | ≤0.10 | |
| Beda backscatter koefisien | dB/km | ≤0.03 | ≤0.03 | ≤0.08 | ≤0.10 | ≤0.08 | ≤0.08 | |
| Keseragaman atenuasi | dB/km | ≤0.01 | ≤0.01 | |||||
| Diaméter inti | um | 9 | 9 | 50±1.0 | 62.5±2.5 | 50±1.0 | 50±1.0 | |
| Diaméter palapis | um | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | 125.0±0.1 | |
| Cladding non-sirkular | % | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | ≤1.0 | |
| Diaméter palapis | um | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | 242±7 | |
| Palapis/leueur kasalahan konsentris | um | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | ≤12.0 | |
| Lapisan non-sirkular | % | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | ≤6.0 | |
| Kasalahan konsentrisitas inti/palapis | um | ≤0.6 | ≤0.6 | ≤1.5 | ≤1.5 | ≤1.5 | ≤1.5 | |
| Curl (radius) | um | ≤4 | ≤4 | ---- | ---- | ---- | ---- | |
Warna serat:
| 1 | 2 | 3 | 4 | 5 | 6 |
| Biru | oranyeu | Héjo | Coklat | Kulawu | Bodas |
| 7 | 8 | 9 | 10 | 11 | 12 |
| Beureum | Hideung | Konéng | Ungu | Pink | Aqua |
Pedaran Kabel GYTS
+ GYTS (anggota panguat logam, tabung leupas anu diuntai sareng dieusi, kabel serat optik luar ruangan anu dilapis baja-polietilen pikeun komunikasi).
+ Struktur kabel optik nyaéta pikeun melapis serat optik mode tunggal atanapi multi-mode kana eusian jero anu didamel tina plastik modulus tinggi. Sanyawa tahan cai dina tabung anu leupas.
+ Pusat inti kabel nyaéta inti anu dikuatkeun ku logam. Pikeun sababaraha kabel serat optik, inti anu dikuatkeun ku logam ogé diekstrusi ku lapisan polietilen (PE).
+ Pipa anu leupas (sareng tali pangisi) dipelintir di sabudeureun inti tulangan tengah pikeun ngabentuk inti kabel anu kompak sareng bunder, sareng celah dina inti kabel dieusi ku sanyawa anu ngahalangan cai.
+ Pita komposit baja-plastik dibungkus sacara longitudinal teras diekstrusi nganggo selubung polietilen.
Konstruksi Kabel GYTS:
Ciri-ciri Kabel GYTS:
+ Kinerja mékanis sareng suhu anu saé
+ Pipa leupas kakuatan luhur anu tahan hidrolisis
+ Sanyawa pangisi tabung khusus mastikeun panyalindungan serat anu penting
+ Struktur kompak anu dirancang khusus saé pikeun nyegah tabung anu leupas tina susut
+ Sarung PE ngajaga kabel tina radiasi ultraviolét
+ Ukuran-ukuran ieu dilaksanakeun pikeun mastikeun kabel kedap cai:
+ Kawat baja anu dianggo salaku anggota kakuatan pusat
+ Senyawa pangisi tabung leupas
+ 100% eusian inti kabel
+ 100% diuji sateuacan dikirim.
+ Panjang gulungan kabel: 1 km, 2 km, 3 km, 5 km
Aplikasi Kabel GYTA:
+ Diadopsi pikeun distribusi Luar Ruangan.
+ Cocog pikeun masang pipa, panguburan langsung, metode handapeun taneuh.
+ Komunikasi jarak jauh sareng jaringan area lokal.
Bungkusan: