10Gb / s SFP + Cable optik aktip
Fitur
+ Rojongan aplikasi 10GBASE-SR / 10G Serat Channel
+ Patuh kana SFP + Eléktro MSA SFF-8431
+ Patuh kana SFP + Mékanis MSA SFF-8432
+ Multi rate nepi ka 11.3Gbps
+ Jarak transmisi dugi ka 150m (OM3)
+ 3.3V catu daya tunggal
+ Konsumsi kakuatan rendah
+ Suhu kasus operasi: Komérsial: 0°C nepi ka +70°C
+ RoHS patuh
+ Perlindungan sandi pikeun A0h sareng A2h
Aplikasi
+ 10GBASE-SR dina 10.31Gbps
+ InfiniBand QDR, SDR, DDR
+ Tumbu optik séjén
Karakteristik listrik
| Parameter | Lambang | Min. | Tip. | Max. | Hijian | Catetan | |
| Pamancar | |||||||
| Diferensial Data Input ayun | Vdi, PP | 200 | - | 1600 | mVPP |
| |
| Input impedansi diferensial | ZIN | 90 | 100 | 110 | Ω |
| |
| Tx_Fault | Operasi Normal | VOL | 0 | - | 0.8 | V |
|
| Kasalahan pamancar | VOH | 2.0 | - | VCC | V |
| |
| Tx_Disable | Operasi Normal | VIL | 0 | - | 0.8 | V |
|
| Laser Nonaktipkeun | VIH | 2.0 | - | VCC+0.3 | V |
| |
| panarima | |||||||
| Kaluaran Tanggal diferensial | Vkaluar | 370 | - | 1600 | mV |
| |
| Kaluaran impedansi diferensial | ZD | 90 | 100 | 110 | Ω |
| |
| Rx_LOS | Operasi Normal | VOL | 0 | - | 0.8 | V |
|
| Kaleungitan Sinyal | VoH | 2.0 | - | VCC | V | ||
Ciri optik
| Parameter | Lambang | Unit | Min | Tip | Max | Catetan |
| Karakteristik pamancar optik | ||||||
| Laju Data | DR | Gbps | 9.953 | 10.3125 | 11.3 |
|
| Puseur Rentang Panjang Gelombang | λc | nm | 820 | 850 | 880 |
|
| Laser Pareum Power | Poff | dBm | - | - | -45 |
|
| Ngajalankeun kakuatan optik | P0 | dBm | -6.0 |
|
| 1 |
| Rasio punah | ER | dB | 3 | - | - |
|
| Lebar spéktral (RMS) | RMS | nm | - |
| 0.45 |
|
| Karakteristik panarima optik | ||||||
| Laju Data | DR | Gbps | 9.953 | 10.3125 | 11.3 |
|
| Laju Kasalahan Bit | BER | dBm | - | - | E-12 | 2 |
| Kakuatan Optik Input Overload | PIN | dBm | 2.4 | - | - | 2 |
| Puseur Rentang Panjang Gelombang | λc | nm | 820 | - | 880 |
|
| Sensitipitas panarima dina kakuatan rata | Sen | dBm | - | - | -9.9 | 3 |
| Los Negeskeun | LosA | dBm | -26 | - | - |
|
| Los De-Assert | LosD | dBm | - | - | -12 |
|
| Los Hysteresis | LosH | dB | 0.5 | - | - | |
Catetan:
- Gandeng kana 50/125 MMF.
- Diukur ku PRBS 231-1 pola uji @10.3125Gbps.BER=10E-12
Ciri optik
| Parameter | Nilai | Hijian |
| diaméterna | 3 | mm |
| Radius tikungan minimum | 30 | mm |
| Toléransi panjang | Panjangna < 1 m: +5 /-0 | cm |
| 1 m ≤ panjangna ≤ 4,5 m: +15 / -0 | cm | |
| 5 m ≤ panjangna ≤ 14,5 m: +30 / -0 | cm | |
| Panjangna≥15,0 m + 2% / -0 | m | |
| Warna kabel | Aqua (OM3); Oranyeu (OM2) | |